Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
010060 E A solid-state drive (SSD) exceeded the warning
temperature threshold.
1217
010061 E A solid-state drive (SSD) exceeded the offline
temperature threshold.
1218
010062 E A drive exceeded the warning temperature threshold. 1217
010063 W Drive medium error. 1321
010066 W Controller indicates that it does not support descriptor
sense for LUNs that are greater than 2 TBs.
1625
010067 W Too many enclosures were presented to a cluster
(system).
1200
010068 E The solid-state drive (SSD) format was corrupted. 1204
010069 E The block size for the solid-state drive (SSD) was
incorrect.
1204
010070 W Too many controller target ports were presented to the
cluster (system).
1200
010071 W Too many target ports were presented to the cluster
(system) from a single controller.
1200
010072 E The drive is offline as a result of a drive hardware error. 1680
010073 E The drive is reporting predictive failure analysis (PFA)
errors.
1680
010080 E The drive is reporting too many errors. 1680
010081 E The drive format is corrupted. 1206
010082 E The block size for the drive was incorrect. 1206
010083 E The drive is offline due to excessive errors. 1680
010084 E The error counts for the SAS drive exceeded the warning
thresholds.
1285
010085 W The SAS device was not recognized. 1666
010086 W The SAS enclosure was not recognized. 1666
010087 W The SAS device was not able to be identified. 1666
010088 E There were excessive medium errors on the drive. 1680
010089 E There were excessive overall timeout errors on the drive. 1680
010090 E There were excessive times when the drive stopped. 1680
010091 E A drive failed validation testing. 1680
010092 E There were excessive medium errors on the solid-state
drive (SSD).
1215
010093 E There were excessive overall timeout errors on the
solid-state drive (SSD).
1204
010094 E Login excluded. 1231
010095 E Drive failed. 1687
010096 E The drive initialization failed because of an unknown
block size or a block size that is not valid; an unknown
capacity or a capacity that is not valid; or was not able to
set the required mode pages.
1680
Chapter 9. Event reporting 123

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
ModelStorwize V7000
Storage TypeHybrid Flash Array
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive TypesSSD, SAS
Host Interface8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI, 12 Gbps SAS
Maximum Cache32GB
Operating System SupportIBM AIX, Linux, Windows, VMware
Data Reduction FeaturesReal-time Compression
Management SoftwareIBM Spectrum Virtualize