Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
010097 E A drive is reporting excessive errors. 1685
010098 W There are too many drives presented to a cluster
(system).
1200
020001 E There are too many medium errors on the managed disk. 1610
020002 E A managed disk group is offline. 1620
020003 W There are insufficient virtual extents. 2030
029001 W The managed disk has bad blocks. 1840
029002 E The system failed to create a bad block because MDisk
already has the maximum number of allowed bad
blocks.
1226
029003 E The system failed to create a bad block because the
clustered system already has the maximum number of
allowed bad blocks.
1225
030000 W The trigger prepare command has failed because of a
cache flush failure.
1900
030010 W The mapping is stopped because of the error that is
indicated in the data.
1910
030020 W The mapping is stopped because of a clustered system or
complete I/O group failure, and the current state of the
relationship could not be recovered.
1895
045001 E One or more power supply unit fans have failed. 1124
045002 E A fan is operating outside the expected range. 1126
045003 E There was a fan status communications failure. 1126
045004 E The power supply unit is not installed. 1128
045005 W The power supply unit has indicated an input power
failure.
1138
045006 E The power supply unit has indicated a dc failure. 1126
045007 E The power supply unit has failed. 1124
045008 E There is no communication with the power supply unit. 1148
045009 E The model type for this enclosure is not valid. 1124
045010 E The power supply unit type is unknown to this product. 1124
045011 E The power supply unit serial number is not valid. 1124
045012 W The canister temperature is at the warning level. 1098
045013 W The canister temperature is at the critical level. 1095
045014 E The SAS cable was excluded because of a missing device. 1260
045015 E A SAS cable was excluded because too many change
events were caused.
1260
045016 E A SAS cable was excluded. 1255
045017 E A SAS cable is operating at a reduced speed. 1260
045018 E A SAS cable was excluded because frames were dropped. 1260
045019 E A SAS cable was excluded because the enclosure
discovery timed out.
1260
045020 W A SAS cable is not present. 1265
124 Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
ModelStorwize V7000
Storage TypeHybrid Flash Array
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive TypesSSD, SAS
Host Interface8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI, 12 Gbps SAS
Maximum Cache32GB
Operating System SupportIBM AIX, Linux, Windows, VMware
Data Reduction FeaturesReal-time Compression
Management SoftwareIBM Spectrum Virtualize