Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
010097 E A drive is reporting excessive errors. 1685
010098 W There are too many drives presented to a cluster
(system).
1200
020001 E There are too many medium errors on the managed disk. 1610
020002 E A managed disk group is offline. 1620
020003 W There are insufficient virtual extents. 2030
029001 W The managed disk has bad blocks. 1840
029002 E The system failed to create a bad block because MDisk
already has the maximum number of allowed bad
blocks.
1226
029003 E The system failed to create a bad block because the
clustered system already has the maximum number of
allowed bad blocks.
1225
030000 W The trigger prepare command has failed because of a
cache flush failure.
1900
030010 W The mapping is stopped because of the error that is
indicated in the data.
1910
030020 W The mapping is stopped because of a clustered system or
complete I/O group failure, and the current state of the
relationship could not be recovered.
1895
045001 E One or more power supply unit fans have failed. 1124
045002 E A fan is operating outside the expected range. 1126
045003 E There was a fan status communications failure. 1126
045004 E The power supply unit is not installed. 1128
045005 W The power supply unit has indicated an input power
failure.
1138
045006 E The power supply unit has indicated a dc failure. 1126
045007 E The power supply unit has failed. 1124
045008 E There is no communication with the power supply unit. 1148
045009 E The model type for this enclosure is not valid. 1124
045010 E The power supply unit type is unknown to this product. 1124
045011 E The power supply unit serial number is not valid. 1124
045012 W The canister temperature is at the warning level. 1098
045013 W The canister temperature is at the critical level. 1095
045014 E The SAS cable was excluded because of a missing device. 1260
045015 E A SAS cable was excluded because too many change
events were caused.
1260
045016 E A SAS cable was excluded. 1255
045017 E A SAS cable is operating at a reduced speed. 1260
045018 E A SAS cable was excluded because frames were dropped. 1260
045019 E A SAS cable was excluded because the enclosure
discovery timed out.
1260
045020 W A SAS cable is not present. 1265
124 Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide