v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 4364 or Type 4365 server,” on page 59 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-event/error log message Action
System shutoff due to +1.5V CPU under voltage
1. Reseat the following components:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
c. Power supply
2.
Replace the following components one at a time, in the order
shown, restarting the server each time:
a. (Trained service technician only) System board
b. (Trained service technician only) Microprocessor
System shutoff due to +2.5v over voltage.
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
System shutoff due to +3.3V over voltage
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
System shutoff due to +3.3V under voltage
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
System shutoff due to +12v over voltage.
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
System shutoff due to +12v under voltage.
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
System shutoff due to continuous +5v over
voltage.
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
System shutoff due to continuous +5v under
voltage.
1. Reseat the following components:
a. (Trained service technician only) System board
b. Power supply
2.
(Trained service technician only) Replace the system board.
Chapter 2. Diagnostics 53

Table of Contents

Other manuals for IBM System x3250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3250 and is the answer not in the manual?

IBM System x3250 Specifications

General IconGeneral
Processor Sockets1
Memory Slots4
ProcessorIntel Core 2 Duo
StorageSATA
Maximum Internal StorageUp to 4TB
Hard Drive InterfaceSATA
RAID SupportRAID 0, 1
NetworkGigabit Ethernet
Operating System SupportWindows Server, Linux

Related product manuals