Code (H) Description
Panel
Indication
Action Required
007C Drive does not enter EJECT state (and media
not ejected) within 200 seconds of a GET
command. Suspect the drive.
CHK 007C 1. If the cartridge does not eject, try to unload the cartridge from the drive with
the Web User Interface (Manage Library > Unload) or the Operator Panel
(Commands > Unload). Move the cartridge from the drive to the I/O Station.
Remove the cartridge from the library and inspect for damage and replace, if
necessary.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
007D Drive does not enter MOUNT state within
200 seconds of a PUT command. Suspect
the drive or X motor.
CHK 007D Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library operations
resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
007E Drive does not enter SET state within 3
seconds of a PUT command. Suspect the
drive or X motor.
CHK 007E
007F Drive I/F or connection error occurs during a
PUT operation or GET operation. Suspect the
drive.
CHK 007F 1. Reseat all cables. See Reseating cables.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
0080 X movement error #1.
During X movement, the target stop
position's origin sensor error detected.
Suspect the X origin sensor or X motor.
CHK 0080 1. Check the accessor locking screw and remove it if it is installed. See Removing
the accessor locking screw.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
0081 X movement error #2.
During X movement, a motor sync error
detected. Suspect the X encoder sensor or X
motor.
CHK 0081
0082 X movement error #3.
During initialization, a motor sync error
detected. Suspect the X encoder sensor or X
motor.
CHK 0082
0083 During an eject operation or move operation
(to a storage position), the X origin sensor is
not detected. Suspect the X origin sensor or
X motor.
CHK 0083
0084 During initialization, the X origin position is
not detected. Suspect the X origin sensor or
X motor.
CHK 0084
0088 X calibration error #1.
During X calibration, centering sensor OFF
condition is not detected.
CHK 0088
0089 X calibration error #2.
During X calibration, centering sensor ON
condition is not detected.
CHK 0089
008F During X operation, the cartridge magazine
was removed. Suspect the magazine set
sensor.
CHK 008F 1. Confirm that the magazine is closed.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
00B0 Failed to detect media in the accessor at
completion of GET operation. Suspect the
centering sensor, X motor, or P motor.
CHK 00B0 1. Confirm the media is compatible. See Table 1.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
00B1 No media is contained in the specified cell
(Cell Empty). Suspect the centering sensor, X
motor, or P motor.
CHK 00B1 Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library operations
resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
00B2 Media detected in the accessor at
completion of centering check operation.
Suspect the centering sensor.
CHK 00B2 1. If the cartridge remains in the accessor, try to move the cartridge from the
accessor to the I/O Station with the Web User Interface or the Operator Panel.
Remove the cartridge from the library and inspect for damage and replace, if
necessary.
2. Cycle the power supply and try again.
If the problem is corrected, run Library Verify before normal library
operations resume. See Running library verify test.
If the problem persists, see Contacting IBM technical support.
00B3 Media detected in the accessor at
completion of PUT operation. Suspect the
centering sensor.
CHK 00B3
TS2900 Tape Autoloader 59