Table 36. Warning events (continued)
Event Code Message Text and Description Details and Solution
4012 Move Cartridge failed due to cartridge
issue.
• View the event details to determine which
cartridge was involved.
• Verify surrounding events that might point to
problems with this media in other move
operations.
• Remove the media from the library, and
physically inspect the media to ensure that
no physical damage exists.
• If the media appears to be undamaged, put
the media back into the library and retry the
move operation. If the problem persists, retry
the operation with a different cartridge in the
same drive.
• If the problem follows the media, remove the
media from use.
• If the problem follows the drive, use the
library Management GUI to pull a drive
support ticket and check the device analysis
section for help.
4014 Library test failed due to a Drive issue.
• Verify the test parameters, and retry the test.
• If the test fails, check the library event log for
speciîš³c events that are associated with this
drive.
• Use the Management GUI to pull a drive
support ticket and check the device analysis
section for help.
4015 Power supply failed. Redundancy isn’t
available.
Ensure that all power supplies are installed
properly (two per module), and that each
power supply is connected to a valid power
source.
4016 Back up conîš³guration data to base module
failed.
Attempt to save the library conîš³guration,
power cycle the library, and retry the operation.
4017 Restore conîš³guration data from Chassis
failed.
Attempt to save the library conîš³guration,
power cycle the library, and retry the operation.
4019 Drive Firmware bundle upgrade failed.
1. Verify that the îš³rmware îš³le is correct for the
drives.
2. Ensure that the drives are in a healthy state
with no cartridge in the drive.
3. Retry the operation.
4020 Database was reset due to a problem that
prevented the library from powering up.
• If the library was restored to default settings,
restore a saved conîš³guration by using a
previously saved conîš³g îš³le.
• If no cong le exists, then proceed in
conîš³guring the library.
96 IBM TS4300 Tape Library Machine Type 3555: User's Guide