Table 36. Warning events (continued)
Event Code Message Text and Description Details and Solution
4065 A tape alert flag was reported by a drive. Look for logged TapeAlert flags and see its
description in the “TapeAlert flags” on page
108 section.
4067 Cleaning cartridge will soon expire and
must be replaced.
Replace the cartridge.
4072 No cleaning cartridge in logical library
available for auto cleaning.
Auto cleaning is enabled, but the logical
library contains no labeled cleaning cartridge.
The library was unable to complete the auto
clean function for one or more drives in this
logical library.
Install a valid and labeled cleaning cartridge
into the logical library and then complete a
load and unload on the drive that needs
cleaning to start the auto cleaning.
4073 Medium source element empty. Check the source slot visually and rescan the
inventory. Additionally, check for valid and
readable bar code label.
4074 Medium source element empty. Check the source slot visually and rescan the
inventory. Additionally, check for valid and
readable bar code label.
4075 Cartridge lost while it was extracted from
slot/drive.
Check the source/destination element and
ensure that no obstructions are in the pathway
of the accessor.
4077 Unlocking the right magazine failed.
Restart the library and retry the operation.
If the error persists, replace the chassis.
If the magazine needs to be removed to get
access to the tape cartridges, rst power
down the device, and then release the
magazine manually. Only one magazine can
be open at a time.
4078 Unlocking the left magazine failed.
Restart the library and retry the operation.
If the error persists, replace the chassis.
If the magazine needs to be removed to get
access to the tape cartridges, rst power
down the device, and then release the
magazine manually. Only one magazine can
be open at a time.
4079 Unlocking the I/O station failed.
Restart the library and retry the operation.
If the error persists, replace the chassis.
If the I/O station needs to be removed to get
access to the tape cartridges, rst power
down the device, and then release the
magazine manually. Only one magazine can
be open at a time.
98 IBM TS4300 Tape Library Machine Type 3555: User's Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS4300 3555 and is the answer not in the manual?

IBM TS4300 3555 Specifications

General IconGeneral
Maximum Number of Drives2
EncryptionYes
Product TypeTape Library
Power SupplyRedundant power supplies
Drive TypeLTO-6
Max Capacity (LTO-6)192 TB (compressed)
WeightApproximately 85 lbs
Operating Temperature10°C to 35°C
InterfaceFibre Channel, SAS
Host InterfaceFibre Channel, SAS