v For information about power-supply problems, see “Solving power problems”
on page 175, “Power problems” on page 166, and “Power-supply LEDs” on page
141.
v For intermittent problems, check the event log; see “Event logs” on page 146 and
Appendix C, “DSA diagnostic test results,” on page 693.
Performing the checkout procedure
Use this information to perform the checkout procedure.
About this task
To perform the checkout procedure, complete the following steps:
Procedure
1. Is the server part of a cluster?
v No: Go to step 2.
v Yes: Shut down all failing servers that are related to the cluster. Go to step 2.
2. Complete the following steps:
a. Check the power supply LEDs (see “Power-supply LEDs” on page 141).
b. Turn off the server and all external devices.
c. Check all internal and external devices for compatibility at
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.
d. Check all cables and power cords.
e. Set all display controls to the middle positions.
f. Turn on all external devices.
g. Turn on the server. If the server does not start, see “Troubleshooting by
symptom” on page 153.
h. Check the system-error LED on the operator information panel. If it is lit,
check the light path diagnostics LEDs (see “Light path diagnostics” on page
134).
i. Check for the following results:
v Successful completion of POST (see “POST” on page 149 for more
information)
v Successful completion of startup, which is indicated by a readable display
of the operating-system desktop
3. Is there a readable image on the monitor screen?
v No: Find the failure symptom in “Troubleshooting by symptom” on page
153; if necessary, see “Solving undetermined problems” on page 177.
v Yes: Run DSA (see “Running the DSA Preboot diagnostic programs” on page
151).
If DSA reports an error, follow the instructions in Appendix C, “DSA
diagnostic test results,” on page 693.
If DSA does not report an error but you still suspect a problem, see
“Solving undetermined problems” on page 177.
Chapter 4. Troubleshooting 131

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 M4 Type 7914 and is the answer not in the manual?

IBM x3550 M4 Type 7914 Specifications

General IconGeneral
Form Factor1U Rack
Memory Slots24 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 or E5-2600 v2 series processors
ChipsetIntel C600 Series Chipset
MemoryUp to 768GB DDR3
RAID SupportRAID 0, 1, 10
Network Interface4 x 1GbE (embedded)
Power SupplyDual hot-swap power supplies (550W, 750W, or 900W)
Expansion SlotsUp to 3 PCIe 3.0 slots
StorageUp to 8 x 2.5" or 4 x 3.5" hot-swap drives