5. Insert the fan into the fan slot in the fan assembly bracket and press it down
until it is seated correctly in the slot and the fan connector is seated correctly in
the connector on the system board.
Note: Make sure that the newly-installed fan aligns horizontally with other
correctly-seated fans for proper installation.
6. Replace the cover (see “Replacing the cover” on page 209).
7. Slide the server into the rack.
Removing a power supply
Use this information to remove a power supply.
Figure 166. Fan installation
270 IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 M4 Type 7914 and is the answer not in the manual?

IBM x3550 M4 Type 7914 Specifications

General IconGeneral
Form Factor1U Rack
Memory Slots24 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 or E5-2600 v2 series processors
ChipsetIntel C600 Series Chipset
MemoryUp to 768GB DDR3
RAID SupportRAID 0, 1, 10
Network Interface4 x 1GbE (embedded)
Power SupplyDual hot-swap power supplies (550W, 750W, or 900W)
Expansion SlotsUp to 3 PCIe 3.0 slots
StorageUp to 8 x 2.5" or 4 x 3.5" hot-swap drives