215-903-000 Optical Drive Test Aborted
Explanation: Optical Drive Test Aborted. Could not access the device.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.
2. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
3. Run the test again.
4. Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
DSA system management test results
The following messages can result when you run the system management test.
166-000-001 IMM I2C Test Passed
Explanation: IMM I2C Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
215-903-000 166-000-001
Appendix C. DSA diagnostic test results 813

Table of Contents