v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom Action
The OVER SPEC LED on the
light path diagnostics panel is
lit, or the Pwr rail 4 error has
been recorded in the IMM
event log.
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail 4 error has been recorded in
the IMM event log:
v Optional PCI adapter power cable (if one is present)
v Fan 1
v Fan 2
v Hard disk drives
v DIMMs 7 through 12
3. Restart the server. If the Pwr rail 4 error has been recorded in the IMM event
log again, (trained technician only) replace the system board (see “Removing
the system board” on page 327 and “Replacing the system board” on page
330).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr Rail 4 error has been recorded in the IMM event
log again, the component that you just reinstalled is defective. Replace the
defective component.
v DIMMs 7 through 12 (see “Removing a memory module” on page 236 and
“Installing a memory module” on page 49).
v Hard disk drives
v Fan 2 (see “Removing a hot-swap fan” on page 267 and “Replacing a
hot-swap fan” on page 268).
v Fan 1
v Optional PCI adapter power cable (if one is present)
5. Follow actions in “Solving power problems” on page 175, if the OVER SPEC
LED on the light path diagnostics panel is still lit.
6. Replace the power supply if the OVER SPEC LED on the light path diagnostics
panel is still lit.
Chapter 4. Troubleshooting 169

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 M4 Type 7914 and is the answer not in the manual?

IBM x3550 M4 Type 7914 Specifications

General IconGeneral
Form Factor1U Rack
Memory Slots24 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
ProcessorUp to two Intel Xeon E5-2600 or E5-2600 v2 series processors
ChipsetIntel C600 Series Chipset
MemoryUp to 768GB DDR3
RAID SupportRAID 0, 1, 10
Network Interface4 x 1GbE (embedded)
Power SupplyDual hot-swap power supplies (550W, 750W, or 900W)
Expansion SlotsUp to 3 PCIe 3.0 slots
StorageUp to 8 x 2.5" or 4 x 3.5" hot-swap drives