EasyManuals Logo
Home>IBM>Server>x3550

IBM x3550 User Manual

IBM x3550
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #120 background imageLoading...
Page #120 background image
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 29 to determine which components are
CRUs and which components are FRUs.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code Description Action
2-2-4 CMOS configuration information checks
failed.
1. Reseat the system-board battery.
2. Clear CMOS. See “System-board switches
and jumpers” on page 11 for more
information about how to clear CMOS.
3. Replace the following components, one at
a time, in the order shown, restarting the
server each time:
a. System-board battery
b. (Trained service technician only)
System board
2-3-1 Screen initialization failed. (Trained service technician only) Replace the
system board.
2-3-2 Screen memory failed. (Trained service technician only) Replace the
system board.
2-3-3 Screen retrace failed. (Trained service technician only) Replace the
system board.
2-3-4 Search for video ROM failed. (Trained service technician only) Replace the
system board.
2-4-1 Video failed. (Trained service technician only) Replace the
system board.
2-4-4 Memory configuration error.
1. Make sure that the DIMMS are installed in
the correct configuration.
2. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Failing DIMM
b. (Trained service technician only)
System board
3-1-1 Timer tick interrupt failed. (Trained service technician only) Replace the
system board.
3-1-2 Interval timer channel 2 failed. (Trained service technician only) Replace the
system board.
3-1-3 RAM test failed above address 0FFFFh.
1. Reseat the DIMMs.
2. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only)
System board
102 IBM System x3550 Type 7978 and 1913: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 and is the answer not in the manual?

IBM x3550 Specifications

General IconGeneral
BrandIBM
Modelx3550
CategoryServer
LanguageEnglish

Related product manuals