v No: Go to step 2.
v Yes: Shut down all failing servers that are related to the cluster. Go to step 2.
2. Complete the following steps:
a. Check the power supply LEDs, see “Power-supply LEDs” on page 140.
b. Turn off the server and all external devices.
c. Check all internal and external devices for compatibility at
http://www.ibm.com/servers/eserver/serverproven/compat/us/.
d. Check all cables and power cords.
e. Set all display controls to the middle positions.
f. Turn on all external devices.
g. Turn on the server. If the server does not start, see “Troubleshooting tables”
on page 123.
h. Check the system-error LED on the operator information panel. If it is
flashing, check the light path diagnostics LEDs (see “Light path diagnostics”
on page 136).
i. Check for the following results:
v Successful completion of POST (see “POST” on page 99 for more
information)
v Successful completion of startup
3. Did one or more beeps sound?
v No: Find the failure symptom in “Troubleshooting tables” on page 123; if
necessary, run the diagnostic programs (see “Running the diagnostic
programs” on page 142).
If you receive an error, see “Diagnostic error codes” on page 144.
If the diagnostic programs were completed successfully and you still
suspect a problem, see “Solving undetermined problems” on page 166.
v Yes: Find the beep code in “POST beep codes” on page 99; if necessary,
see “Solving undetermined problems” on page 166.
122 IBM System x3550 Type 7978 and 1913: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 and is the answer not in the manual?

IBM x3550 Specifications

General IconGeneral
Processor TypeIntel Xeon
ChipsetIntel 5000P
Number of Processors Supported2
Network InterfaceDual Gigabit Ethernet
Hard Drive InterfaceSAS/SATA
Maximum Internal Storage2.4 TB
StorageUp to six 2.5-inch SAS or SATA hot-swap hard disk drives
Drive Bays6
RAID SupportRAID 0, 1
Power Supply670W or 835W
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESX
MemoryPC2-5300 Fully Buffered DIMMs (DDR2-667) or PC2-4200 Fully Buffered DIMMs (DDR2-533)