14 Factory setting
Factory setting User setting
Global settings
Input filter 10 Hz high pass
Characteristic vibration
value 1
Filter 1000 Hz low pass
Evaluation method RMS
Degree of integration Vibration velocity
Measurement time 0�25 s
History interval 300 s
History values Maximum value + average
value
Characteristic vibration
value 2
Filter 6000 Hz low pass
Evaluation method Peak
Degree of integration Acceleration
Measurement time 0�25 s
History interval 300 s
History values Maximum value + average
value
External input
Usage Analogue signal
Scaling VNA (if used =
VNA)
Not used
Input filter (if used = VNA) Not used
External process value 1
Measurement time 0�5 s