20
CE, cTUVus, EN50191(Models 3705, 3765,3770 ),
RoHS2
Remote Input-Output
Control
The following input and output signals are provided
through two 9 pin D-type connectors:
1. Remote control: Test, Reset, and Remote
Interlock.
2. Remote recall of memory program 1, 2 and 3
3. Outputs: Pass, Fail, Test-in-Process, and Reset
10 memories, 3 steps per memory, all steps within a
memory are linkable.
Key Lock capability to avoid unauthorized access to
all test parameters. Memory Lock capability to avoid
unauthorized access to memory locations.
Built-in Smart GFI circuit
128 x 64 dot resolution with front panel contrast
setting.
Front panel adjustable volume setting with 10 set
points.
Detachable 7 ft. (2.13m) power cable terminated in a
three prong grounding plug.
Detachable 5ft.(1.52m) high voltage and return leads
(2) with clips and a standard U.S. style (NEMA 5-15)
remote receptacle box for testing items terminated
with a line cord. International receptacles also
available. Front and Rear outputs standard.
Tilt up front feet.
Dimensions: (W x H x D) (215 x 89 x 370 mm)
(3705,3765,3770)
Dimensions: (W x H x D) (430 x 133 x 350 mm)
(3780)
Weight: 20.96 lbs. (9.53Kgs) (3705,3765,3770)
Weight: 49lbs. (22.23Kgs) (3780)
Operating Temperature : (0 - 40C)
Relative Humidity - 0 to 80%
Traceable to National Institute of Standards and
Technology (NIST). Calibration controlled by
software. Adjustments are made through front panel
keypad in a restricted access calibration mode.
Calibration information stored in non-volatile memory.