L001—Focus images
InstrumentAnalyticsLogs—Log files describing instrument analytics steps
InterOp—Binary files used by Sequencing Analysis Viewer
Logs—Log files describing operational steps
Recipe—Run-specific recipe file named with reagent cartridge ID
RTALogs—Log files describing analysis steps
RTAComplete.xml
RTAConfiguration.xml
RunInfo.xml
RunNotes.xml
RunParameters.xml
Analysis Input File Requirements
Local Run Manager requires the following files generated during the sequencing run to perform analysis or to
requeue analysis. Some analysis modules require additional input files to perform analysis. For more
information, see the workflow guide for the analysis module you are using.
File Name / Type Description
RTAComplete.txt A marker file that indicates RTA processing is complete. The presence of this file triggers
Local Run Manager to queue analysis.
RunInfo.xml Contains high-level run information, such as the number of reads and cycles in the
sequencing run, and whether a read is indexed.
Base call files (*.bcl) Contains the base call and encoded quality score for every cluster for each tile,
aggregated in a file for each cycle.
Filter files (*.filter) Specifies whether a cluster passed filters. Filter information is aggregated into a filter file
for each read.
Cluster location files (*.locs) Contains the XY coordinates for every cluster for each tile, aggregated into a cluster
location file
Document # 1000000002695 v02 Material # 20014309
For Research Use Only. Not for use in diagnostic procedures.
53
MiniSeq System Guide

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the illumina MiniSeq and is the answer not in the manual?

illumina MiniSeq Specifications

General IconGeneral
Instrument TypeBenchtop Sequencer
Sequencing TechnologySequencing by Synthesis (SBS)
Read LengthUp to 2 x 150 bp
OutputUp to 7.5 Gb
Run Time4 - 24 hours
Data Quality≥ 80% bases ≥ Q30
Maximum Reads25 million
Sample Capacity1
ApplicationsTargeted Gene Sequencing, Small Genome Sequencing, Amplicon Sequencing, Gene Expression Profiling
Power Requirements100-240 V, 50-60 Hz
Operating Temperature19°C to 25°C
Operating HumidityNon-condensing, 20% to 80% RH