4.9.9. Trigger Mode 5
This mode is “multiple shutter pulse width mode”. The camera starts the integration of the incoming light from the
first external trigger input falling edge and exposes incoming light until the trigger is inactive. It repeats this
sequence for the ‘N’th (parameter) external trigger input falling edge and then finishes the integration. A
Parameter is required and shall be one or more. (N >= 1)
4.9.10. Trigger Mode 12
The user can capture the multi frame rates with one trigger signal. The users can control the Gain and Shutter by
the Parameter Table which has a range from 1 to 255. Mode 12 is supported by both a H/W trigger and a S/W
trigger.