IS300 Series Servo Drive User Manual Product Information
- 21 -
Adapted Servo
Drive Model
A B C D E F G
Mounting
Hole
Copper Medal
Connecting
Hole Diameter
Reactor
Model
IS300-2T300-C
160 190 125 161 192 255 195 10*15 Ø12 DCL-0360
IS300T250-C,
IS300T300-C
IS300-5T250-C,
IS300-5T300-C
IS300T370-C,
IS300T420-C
190 230 93 128 250 325 200 13*18 Ø15 DCL-0600
IS300-5T370-C,
IS300-5T420-C
IS300T460-C,
IS300T520-C
190 230 93 128 250 325 200 13*18 Ø15 DCL-0700
IS300-5T460-C,
IS300-5T520-C
IS300T580-C,
IS300T650-C,
IS300T720-C
224 250 135 165 260 330 235 12*20 Ø14 DCL-1000
IS300-5T580-C,
IS300-5T650-C,
IS300-5T720-C
How to Install External DC Reactor
The IS300 servo drives of IS300(*)140-C-* and above are configured with external DC
reactor as standard. The DC reactor is packed in separate wooden box for delivery.
When installing the DC reactor, please remove the short circuit cooper bar between the
main circuit connection terminal P and (+). Then connect the DC reactor between terminals
P and (+) with no polarity requirement. The copper bar will not be used any longer once the
installation is complete.