IS300 Series Servo Drive User Manual Operation and Display
- 39 -
In Level III menu, if the parameter has no ashing bit, it means that the parameter cannot be
modified. This may be because:
• Such function code is readable parameter, like inverter type, actually detected
parameter and running record parameter.
• Such function code cannot be modified in the running status and can only be changed
after the inverter stops.
4.3 QUICK Operation
The QUICK key on the operation panel enables you to query the parameters in the shortcut
menu. The setup of the shortcut menu is aimed to facilitate the user to query and modify the
commonly used parameters quickly.
The parameter is displayed as "uA3-01" in the shortcut menu, indicating parameter A3-01.
Modification of parameter in the shortcut menu has the same effect as the modification in
common status.
Up to 16 parameters can be saved in the shortcut menu. If there have been 16 parameters,
"FULL" will be displayed for new adding. If "NULL" is displayed, it indicates that the shortcut
menu is null. The operation of the shortcut menu is restricted by F7-03. If F7-03 is set to
0, you can increase/decrease parameters in the shortcut menu. If it is set to 1, you cannot
perform increment/decrement operation.
A total of 16 parameters are stored in the shortcut menu after initialization, shown as below:
uA3-01 Max. rotational sped uA3-09 Bottom ow
uA3-02 System oil pressure uA3-10 Bottom pressure
uA3-03 Max. oil pressure uA3-11 AI null shift atuto correction
uA3-04 Oil pressure command rise time uA3-12 Speed loop proportional gain 1
uA3-05 Oil pressure control Kp1 uA3-13 Speed loop integral time 1
uA3-06 Oil pressure control Ti1 uA3-14 Speed loop proportional gain 2
uA3-07 Oil pressure control Td1 uA3-15 Speed loop integral time 2
uA3 Max. reverse rotational sped uA3-16 AI3 input filter time
4.3.1 Saving Parameters to Shortcut Menu
50.00 F0
PRG
F0-16
QUICK
F0-16
ENTER
F0-16
Flashing Flashing stops
Stop display
Press the QUICK key in the Level II menu of PRG. The display ashes to prompt whether
to save the parameter to the shortcut menu. Then if you press ENTER, the display stops
ashing and the saving is complete. If you press PRG, the display stops ashing and the
saving is cancelled.