Operation and Display IS300 Series Servo Drive User Manual
- 40 -
4.3.2 Modifying Parameters in Shortcut Menu
50.00 uF0-12
QUICK
uF1-04
Stop or running
display
QUICK
uF5-06
QUICK ENTER
01
ENTER
QUICK
uF5-06
On the stop or running display interface, press QUICK to enter the shortcut menu. Then you
can select the parameter via the UP/DOWN key. Then press ENTER to enter the Level III
menu. Here the parameter modification is the same as that in common Level III menu. To
return to Level II menu, press QUICK. The modification will not be saved.
4.3.3 Deleting Parameters from Shortcut Menu
50.00 uF0-12
QUICK
uF1-04
QUICK
uF5-06
ENTER
uF5-06
QUICK
PRG
Flashing display
uF8-01
50.00
In the shortcut menu, press PRG. The display flashes to prompt whether to delete the
parameter. Then if you press ENTER, the display stops flashing and the deletion is
complete. If you press QUICK, the display stops ashing and the deletion is cancelled. If the
last shortcut parameter is deleted, "Null" will be displayed then.
4.4 Querying Status Parameters
In the stop or running status, parameters in multiple statuses can be displayed. You can
select whether to display the parameter according to selection of the binary bits of F7-04
(running parameters) and F7-05 (stop parameters).
In the running status, five running status parameters are always displayed, namely, running
frequency, set frequency, bus voltage, output voltage and output current. Whether the other
16 parameters are displayed is determined by the setting of F7-04. The 16 parameters
include DI input status, DO output status, AI1 voltage, AI2 voltage, AI3 voltage (current)
and 4 reserved parameters. Press the key to switchover the display of the parameters in
sequence.
In the stop status, a total of 16 stop status parameters can be selected, namely, set
frequency, bus voltage, DI input status, DO output status, AI1 voltage, AI2 voltage, AI3
voltage (current) and 5 reserved parameters. Whether to display the 16 parameters
is determined by the setting of F7-05. Press the key to switchover the display of the
parameters in sequence.
When the servo drive is re-powered on after power failure, the displayed parameters are the
parameters selected before the power failure by default.