IS300 Series Servo Drive User Manual Troubleshooting
- 49 -
Err14 (Module Overheat)
Err14
Check whether ambient temperature is too high .
No
Lower ambient temperature
Yes
Check whether the module thermistor is broken .
Replace the thermistor .
Yes
No
Check whether the inverter module is broken .
Replace the inverter module .
Yes
Contact the agent
or our company.
Clear the air filter .
Yes
Check whether the air filter is blocked .
Replace the cooling fan .
Yes
Check whether the cooling fan is broken .
No
No
Err15 (External Machine Fault)
Err15
Check whether pressing STOP key in
the non-operation panel mode .
Reset the fault.
Yes
Check and eliminate
external faults .
Yes
Check whether external fault signal
is input via DI terminal .
Reset the fault.
Yes
Check whether pressing STOP key
in case of stall .
No
No