EasyManua.ls Logo

Inovance IS 300 Series - 5.2 Common Faults and Solutions

Inovance IS 300 Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting IS300 Series Servo Drive User Manual
- 54 -
Err46 (Oil Pressure Transducer Fault)
Err46
Eliminate wiring fault .
Eliminate power supply fault.
Replace oil pressure
transducer.
Yes
No
No
No
Yes
Yes
It is terminal block fault .
Yes
Contact the agent
or our company.
Check whether the oil pressure
transducer wiring is wrong .
Check whether the power supply of the
oil pressure transducer is normal .
Check whether the output of the oil
pressure transducer is normal .
Check whether it it normal after the
terminal block is replaced .
Err49 (Resolver Signal Fault)
Err49
Eliminate wiring fault .
Eliminate wiring fault .
It is PG card fault .
Yes
No
No
Yes
Yes
Contact the agent
or our company.
Check whether the connecting joint of
the PG card and resolver falls off .
Check whether the wiring of the PG
card and resolver is proper .
Check whether it it normal after the PG
card is replaced.
Err58 (Parameter Restoration Error)
Note
Err47, Err48 and Err52 are the faults that occur when multiple pumps are connected in
parallel. In single pump control mode, please cut off the input of DI5.
If multi-pump parallel control shall be adopted, contact Inovance for the "multi-pump control
solution" and refer to the description.