6. Parameter Table MD500 User Manual
- 100 -
Function Code Parameter Name Setting Range Default Property
A2-63 Motor 2 torque boost À[HGWRUTXHERRVW
0.1% to 30.0%
Model
dependent
ƿ
A2-65 Motor 2 oscillation
suppression gain
0 to 100 Model
dependent
ƿ
Group A5: Control Optimization
A5-00 DPWM switchover
frequency upper limit
5.00 Hz to max. frequency 8.00 Hz
ƿ
A5-01 PWM modulation pattern 0, 1 0
ƿ
A5-02 Dead zone compensation
mode selection
0, 1 1
ƿ
A5-03 Random PWM depth 0 to 10 0
ƿ
A5-04 Selection of fast current limit 0, 1 1
ƿ
A5-05 Current detection compensation 0 to 100 5
ƿ
A5-06 Undervoltage threshold 210 to 420 V 150%
ƿ
A5-08 'HDG]RQHWLPHDGMXVWPHQW 100% to 200% 0
ƾ
$ Overvoltage threshold 200.0 to 2500.0 V Model
dependent
ƾ
Group A6: AI Curve Setting
A6-00 AI curve 4 min. input -10.00 V to A6-02 0.00 V
ƿ
A6-01 Corresponding percentage
of AI curve 4 min. input
-100.0% to 100.0% 0.0%
ƿ
A6-02 $,FXUYHLQÁH[LRQLQSXW A6-00 to A6-04 3.00 V
ƿ
A6-03 Corresponding percentage of
$,FXUYHLQÁH[LRQLQSXW
-100.0% to 100.0% 30.0%
ƿ
A6-04 $,FXUYHLQÁH[LRQLQSXW A6-02 to A6-06 6.00 V
ƿ
A6-05 Corresponding percentage of
$,FXUYHLQÁH[LRQLQSXW
-100.0% to 100.0% 60.0%
ƿ
A6-06 AI curve 4 max. input A6-04 to 10.00 V 10.00 V
ƿ
A6-07 Corresponding percentage
of AI curve 4 max. input
-100.0% to 100.0% 100.0%
ƿ
A6-08 AI curve 5 min. input -10.00 V to A6-10 -10.00 V
ƿ
$ Corresponding percentage
of AI curve 5 min. input
-100.0% to 100.0% -100.0%
ƿ
A6-10 $,FXUYHLQÁH[LRQLQSXW A6-08 to A6-12 -3.00 V
ƿ
A6-11 Corresponding percentage of
$,FXUYHLQÁH[LRQLQSXW
-100.0% to 100.0% -30.0%
ƿ
A6-12 $,FXUYHLQÁH[LRQLQSXW A6-10 to A6-14 3.00 V
ƿ
A6-13 Corresponding percentage of
$,FXUYHLQÁH[LRQLQSXW
-100.0% to 100.0% 30.0%
ƿ
A6-14 AI curve 5 max. input A6-12 to 10.00 V 10.00 V
ƿ
A6-15 Corresponding percentage
of AI curve 5 max. input
-100.0% to 100.0% 100.0%
ƿ
A6-24 Jump point of AI1 input
corresponding setting
-100.0% to 100.0% 0.0%
ƿ
A6-25 Jump amplitude of AI1 input
corresponding setting
0.0% to 100.0% 0.5%
ƿ
A6-26 Jump point of AI2 input
corresponding setting
-100.0% to 100.0% 0.0%
ƿ
A6-27 Jump amplitude of AI2 input
corresponding setting
0.0% to 100.0% 0.5%
ƿ
A6-28 Jump point of AI3 input
corresponding setting
-100.0% to 100.0% 0.0%
ƿ
efesotomasyon.com