7. Description of Parameters MD500 User Manual
- 148 -
Function Code Parameter Name Setting Range Default
F1-28 Encoder type 0: ABZ incremental encoder
2: Resolver
0
F1-28: Different types of encoders require different PG cards. Set this function parameter correctly after installation of a proper PG
card is completed. Otherwise, the AC drive may run abnormally.
Function Code Parameter Name Setting Range Default
F1-30 $%SKDVHVHTXHQFHRI$%=
incremental encoder
0: Forward
1: Reserve
0
)VHWVWKH$%SKDVHVHTXHQFHRI$%=LQFUHPHQWDOHQFRGHUDQGWKXVLVYDOLGIRU$%=LQFUHPHQWDOHQFRGHU)
ƕ F1-30 = 0: Forward
Phase A is ahead for forward motor rotation. Phase B is ahead for reverse motor rotation.
ƕ F1-30 = 1: Reverse
Phase B is ahead for forward motor rotation. Phase A is ahead for reverse motor rotation.
Function Code Parameter Name Setting Range Default
F1-31 Encoder installation angle WR 0.0°
Function Code Parameter Name Setting Range Default
F1-34 Number of pole pairs of resolver 1 to 65535 1
F1-34: If a resolver is applied, set the number of pole pairs of the resolver properly.
Function Code Parameter Name Setting Range Default
F1-36 Encoder wire-break
fault detection time
0.0s: No detection
0.1s to 10.0s
0.0s
F1-36 sets the wire-break detection time. If it is set to 0.0s, the detection is disabled. If the wire-break detection time exceeds the
value set in F1-36, the AC drive reports Err20.