EasyManua.ls Logo

Inovance MD500T75G - Page 169

Inovance MD500T75G
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD500 User Manual 7. Description of Parameters

Function Code Parameter Name Setting Range Default
F7-03 LED display running
parameters 1
0000 to FFFF
7 6 5 4 3 2 1 0
Running frequency 1 (Hz)
Frequency reference (Hz)
Bus voltage (V)
Output voltage (V)
Output current (A)
Output power (kW)
Output torque (%)
DI state (V)
15 14 12 11 10 8
DO state
AI1 voltage (V)
Count value
Length value
Load speed display
PID reference
13
AI2 voltage (V)
AI3 voltage (V)
If a parameter needs to be displayed during the
running, set the corresponding bit to 1, and set
F7-03 to the hexadecimal equivalent.
1F
F7-04 LED display running
parameters 2
0000 to FFFF
7 6 5 4 3 2 1 0
PID feedback
PLC stage
Pulse reference (kHz)
Running frequency 2
Remaining running time
AI1 voltage before correction
AI2 voltage before correction
AI3 voltage before correction
15 14 12 11 10 8
Linear speed
Current power-on time (H)
Current running time (Min)
Pulse reference (Hz)
Communication reference
Encoder feedback speed (Hz)
Main frequency display (Hz)
Auxiliary frequency display (Hz)
13
If a parameter needs to be displayed during the
running, set the corresponding bit to 1, and set
F7-04 to the hexadecimal equivalent.
0