MD500 User Manual 7. Description of Parameters
- 181 -
Figure 7-54 The user programmable use schematic (2)
Set the
drive
outputs.
FMR
(FM used as digital
output)
Relay1
(TA-TB-TC)
DO1
FMP
(FM used as pulse
output)
AO1
Control mode
Unit's digit of
A7-01
Control mode
Ten's digit of
A7-01
Control mode
Hundred's
digit of A7-01
Control mode
Thousand's
digit of A7-01
0
1
AC drive control
(See details in group
F5)
PLC program
control
PLC controls
digital output
(unit's digit of A7-05)
0
1
AC drive control
(See details in group
F5)
PLC program
control
PLC controls
digital output
(Ten's digit of A7-05)
0
1
AC drive control
(See details in group
F5)
PLC program
control
PLC controls
digital output.
(unit's digit of A7-05)
0
1
AC drive control
(See details in group
F5)
PLC program
control
PLC controls
FMP output.
(A7-03)
0.0% to 100.0%
The base value of the
percentage is the FMP output
max. frequency (F5-).
0
1
AC drive control
(See details in group
F5)
PLC program
control
PLC controls AO1 output
(A7-04)
0.0% to 100.0%
The base value of the
percentage is 10 V or 20 mA.
PLC program modified
A7-00 = 1
Set the programmable
card to active.
0: output invalid
1: output valid
0: output invalid
1: output valid
0: output invalid
1: output valid
Control mode
Ten thousand's
digit of A7-01
Figure 7-55 The user programmable use schematic (3)
Command
ǂ0: No command
ǂ1: Forward run
ǂ2: Reverse run
ǂ3: )RUZDUGMRJ
ǂ4: 5HYHUVHMRJ
ǂ5: Coast to stop
ǂ6: Decelerate to stop
ǂ7: Fault reset
PLC program modified
Frequency
reference
PLC program modified
Torque
reference
PLC program modified
Fault
PLC program modified
ǂ0: No fault
ǂ80 to : User-defined
A7-00 = 1
Set the programmable
card to active.
The frequency reference is
set via communication.
For details, see section 6.2.
The running command is
given by the
communication.
Set F0-02 = 2.
The frequency reference is set
via communication.
For details, see F2-and A0-
01.
The value of A7-08 is
determined by the user
programmable card.
The value of A7-07 is
determined by the user
programmable card.
The value of A7-06 is
determined by the user
programmable card.
fault code
The value of A7-is
determined by the user
programmable card.
-200.0% to 200.0%
The base value of the percentage
is rated motor torque.
-100.0% to 100.0%
The base value of the percentage
is F0-10 (Max. frequency).
efesotomasyon.com