7. Description of Parameters MD500 User Manual
- 182 -
1. Set whether the user programmable card is valid.
Function Code Parameter Name Setting Range Default
A7-00 User programmable
function selection
0: Disabled
1: Enabled
0
2. Set the AI3 and AO2 function on the user programmable card.
Function Code Parameter Name Setting Range Default
A7-02 User programmable card AI3
and AO2 function selection
0 to 7
0: AI3 (voltage input), AO2 (voltage output)
1: AI3 (voltage input), AO2 (current output)
2: AI3 (current input), AO2 (voltage output)
3: AI3 (current input), AO2 (current output)
4: AI3 (PTC input), AO2 (voltage output)
5: AI3 (PTC input), AO2 (current output)
6: AI3 (PT100 input), AO2 (voltage output)
7: AI3 (PT100 input), AO2 (current output)
0
The user programmable card provides an analog input terminal AI3 and an analog output terminal AO2. Set the DIP switch S1, the
MXPSHU-DQGWKHMXPSHU-RQWKHFDUGDQGWKHQSHUIRUPFRUUHVSRQGLQJVHWWLQJLQ$7KHVHWWLQJRI66DQG-PXVWEH
consistent with the setting in A7-02. Otherwise, the communication will be abnormal.
3. Set the AC drive output signals
When A7-00 = 1 (the user programmable card is enabled), you can set the control source of the output terminals (FMR, relay, DO1,
FMP and AO1) of the AC drive in A7-01.
When an output terminal is controlled by the PLC program, the output of the terminal is determined by the setting of corresponding
IXQFWLRQSDUDPHWHU$$$
<RXFDQLPSOHPHQWFRQWURORIWKHRXWSXWWHUPLQDOYLDWKH3/&SURJUDPE\PRGLI\LQJ$$$
Function Code Parameter Name Setting Range Default
A7-01 AC drive output terminal
control source selection
00000 to 11111
0: AC drive control
1: PLC program control
00000
Unit's digit: FMR (FM used as digital output)
7HQVGLJLW5HOD\7$7%7&
Hundred's digit: DO1
Thousand's digit: FMP (FM used as pulse control)
Ten thousand's digit: AO1
A7-03 PLC program controls
the FMP output
0.0% to 100.0% 0.0%
A7-04 PLC program controls
the AO1 output
0.0% to 100.0% 0.0%
A7-05 Selection of PLC program
controlling digital output
000 to 111
0: Disabled
1: Enabled
000
Unit's digit: FMR
Ten's digit: Relay
Hundred's digit: DO1
7KHEDVHYDOXHRI$LV)0D[)03RXWSXWIUHTXHQF\7KHEDVHYDOXHRI$LV9YROWDJHRXWSXWRUP$FXUUHQW
output).