EasyManua.ls Logo

Inovance MD500T75G - Page 194

Inovance MD500T75G
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. Description of Parameters MD500 User Manual

Function Code Parameter Name Setting Range Default
F4-35 DI1 delay
0.0s to 3600.0s
0.0s
F4-36 DI2 delay
0.0s to 3600.0s
0.0s
F4-37 DI3 delay
0.0s to 3600.0s
0.0s
When the state of DI terminals changes, these three function parameters set the delay time of the change. Now the MD500 supports
the delay function on DI1, DI2 and DI3 only.
Function Code Parameter Name Setting Range Default
F4-38 DI active mode selection 1
0: High level active
1: Low level active
00000
Unit's digit: DI1 active mode
Ten's digit: DI2 active mode
Hundred's digit: DI3 active mode
Thousand's digit: DI4 active mode
Ten thousand's digit: DI5 active mode
) DI active mode selection 2
0: High level active
1: Low level active
00000
Unit's digit: DI6 active mode
Ten's digit: DI7 active mode
Hundred's digit: DI8 active mode
7KRXVDQGVGLJLW',DFWLYHPRGH
Ten thousand's digit: DI10 active mode
These two function parameters set the active mode of DI terminals.
ƕ 0: High level active
If a high level voltage is applied to DI terminal, the DI signal will be seen as active. That is, the DI terminal becomes active
when being connected with COM, and inactive when being disconnected from COM.
ƕ 1: Low level active
If a low level voltage is applied to DI terminal, the DI signal will be seen as active. That is, the DI terminal becomes active when
being disconnected from COM, and inactive when being connected with COM.
efesotomasyon.com

Table of Contents

Related product manuals