7. Description of Parameters MD500 User Manual
- 214 -
$FFHOHUDWLRQ'HFHOHUDWLRQ7LPH6ZLWFKRYHU)UHTXHQF\3RLQW
7KLVIXQFWLRQVHOHFWVWKHDFFHOHUDWLRQGHFHOHUDWLRQWLPHDFFRUGLQJWRWKHUXQQLQJIUHTXHQF\UDQJHGXULQJWKHGULYHUXQQLQJ7KLV
IXQFWLRQLVDFWLYHRQO\ZKHQPRWRULVVHOHFWHGDQGDFFHOHUDWLRQGHFHOHUDWLRQWLPHLVQRWVZLWFKHGRYHUYLDH[WHUQDO',WHUPLQDO
)LJXUH$FFHOHUDWLRQ'HFHOHUDWLRQWLPHVZLWFKRYHU
F8-25
F8-26
Time (t)
Frequency
reference
Output
frequency (Hz)
Acceleration
time 2
Acceleration
time 1
Deceleration
time 1
Deceleration
time 2
During acceleration, if the running frequency is below F8-25, acceleration time 2 is selected. If it is above F8-25, acceleration time 1
is selected.
During deceleration, if the running frequency is above F8-26, deceleration time 1 is selected. If it is below F8-26, deceleration time
2 is selected.
Function Code Parameter Name Setting Range Default
F8-25
Frequency point of switchover
of acceleration time 1 and
acceleration time 2
0.00 Hz to max. frequency
0.00 Hz
F8-26
Frequency point for switchover
of deceleration time 1 and
deceleration time 2
0.00 to max. frequency
0.00 Hz