9. Peripherals and Options MD500 User Manual
- 248 -
([WHQVLRQ,2&DUG0',2
Ƶ
Overview
MD38IO1 is developed by Inovance and is designed for extension of input and output terminals of the MD500 drive.
Item 6SHFLÀFDWLRQ Description
Input terminals Five digital input (DI) terminals 6XSSRUWVWR9GXDOSRODULW\LQSXW
One analog input (AI) terminal
that supports voltage input
Supports -10 to 10 V input.
Output terminals One relay output terminal 250 VAC, 3 A; 30 VDC, 1 A
One digital output (DO) terminal 0 to 24 V, 0 to 50 mA, Optically-coupled isolation
One analog output (AO) terminal 0 to 10 V, 0 to 20 mA
Communication RS485 communication interface Supports the Modbus-RTU communication
protocol (see Appendix I: MD500 Modbus
Communication Protocol for details).
CAN communication interface Supports the CANlink communication protocol.
Ƶ
Physical Appearance
Ƶ
Mechanical Installation
The MD38IO1 an embedded extension card. Power off the drive and wait for a period of 10 minutes until the charging indicator
goes off before starting the installation work.
$VVKRZQLQWKHIROORZLQJÀJXUHLQVHUWWKH0',2FDUGLQWRWKHGULYHDQGÀ[LWZLWKWKHSUHSDUHGVFUHZV
Note
Never install or remove the MD38IO1 card at power-on. In dry season, touch the nearest grounding body to discharge before
contacting the extension card so as to prevent damage to components of the card caused by human static electricity.