3. Electrical Installation MD500 User Manual
- 48 -
Installation of the cable bracket is as follows:
1
2
1 Remove the front cover.
2
Remove the two M4*12 screws
from the air inlet plate.
3
3
Mount the cable bracket to the drive
and take three M4*12 screws to fix the
bracket at the positions here.
3
4
4
Take two M4*12 screws to fix the
bracket at the positions here.
5
5
Reattach the front cover to complete the installation.
ƕ 7KHFDEOHVSHFLÀFDWLRQDQGLQVWDOODWLRQRIDOOFDEOHVFRQQHFWHGWRWKH$&GULYHRXWSXW89:PXVWFRPSO\ZLWKORFDO
safety regulations and relevant IEC standards.
ƕ Use power cables that have copper conductors of the proper size.
ƕ To avoid the risk of equipment damage or operating faults, do not connect a capacitor or surge absorber to the output of
the AC drive.
ƕ Long motor cables can contribute to electrical resonance caused by distributed capacitance and inductance. In some
cases this might cause equipment damage in the AC drive, in the motor or in the cables. To avoid these problems, install
an AC output reactor near to the AC drive if the cable run to the motor is longer than about 100 m.
ƕ Make the lead-out wire at the stripped end of the motor cable as short as possible. The diameter of the lead-out wire must
EHHTXDOWRRUJUHDWWKDQRQHÀIWKRILWVOHQJWK
a
b
b 15·a
efesotomasyon.com