4. Operations MD500 User Manual
- 68 -
4.4.3 Password Security
7KH0'$&GULYHSURYLGHVDVHFXULW\SURWHFWLRQIXQFWLRQWKDWUHTXLUHVDXVHUGHÀQHGSDVVZRUG)XQFWLRQSDUDPHWHU)3
controls this function.
When FP-00 has the default value zero, it is not necessary to enter a password to program the MD500.
To enable the password protection, do as follows:
1. 6HWDQRQ]HURYDOXHIRU)37KLVYDOXHLVWKHXVHUGHÀQHGSDVVZRUG
2. Make a written note of the value you have set for FP-00 and keep the note in a safe location.
3. Press
ENTER
to exit the function parameter editing mode.
The password protection is successfully enabled. Then when you press
PRG
, the display shows "------". You must enter the
correct password to enter the programming menu.
To remove password protection, do as follows:
1. Use the current password to enter the function parameter editing mode.
2. Set FP-00 to zero.
3. Press
ENTER
to exit the function parameter editing mode.
The password protection is successfully removed.
7KHIROORZLQJÀJXUHJLYHVDQH[DPSOHVKRZLQJKRZWRVHWWKHSDVVZRUGWR