5. Quick Setup MD500 User Manual
- 72 -
CONTINUE Para. Parameter name Default Commission
If an encoder is used
Set encoder parameters
F1-27 Encoder pulses per revolution 1024
1 to 65535ppr
F1-28 Encoder type 0
0: ABZ incremental encoder
1: UVW incremental encoder
2: Resolver
6,1&26HQFRGHU
4: Wire-saving UVW encoder
F1-30 $%SKDVHVHTXHQFHRI$%=HQFRGHU 0
0: Forward
1: Reserve
F1-31 Encoder installation angle 0.0
WR
F1-34 Number of pole pairs of resolver 1
1 to 65535 pairs of poles
Perform motor auto tuning
F1-37 Auto-tuning selection 0
0: No auto-tuning
1: Asynchronous motor static auto-tuning 1
2: Asynchronous motor dynamic auto-tuning
3: Asynchronous motor static auto-tuning 2
NOTE: Motor won’t rotate at this stage if choose 1 or 3, for
they are both static, while if choose 2 then motor will rotate,
so better disconnect load from motor shaft for safety.
Steps of auto-tuning:
1. Make sure the UVW connection between inverter and
motor is not disconnected by output contactor; if it is,
then manually handle with the output contactor;
2. Set F0-02=0 (Operation panel control), so that the
key
RUN
can start the tuning procedure.
3. Set F1-37=1 or 2 or 3, press
ENTER
, then LED on panel will display letters
"
TUNE".
4. Press the key
RUN
on panel, then motor starts auto-
WXQLQJLWXVXDOO\WDNHVDERXWVHFRQGVWRÀQLVKWKLVDXWR
tuning, wait until LED stops displaying "TUNE".
Select command source
F0-02 Command source selection
1
2SHUDWLRQSDQHOFRQWUROLQGLFDWRU¶/2&$/5(027·WXUQV2))
7HUPLQDOFRQWUROLQGLFDWRU¶/2&$/5(027·WXUQV21
&RPPXQLFDWLRQFRQWUROLQGLFDWRU¶/2&$/5(027·WXUQVEOLQNLQJ
Select control mode
F0-01 Control mode selection
0
0: SVC control
1: FVC control
2: VF control
CONTINUE Para. Parameter name Default Commission