EasyManua.ls Logo

Inovance MD500T75G - Page 88

Inovance MD500T75G
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Parameter Table MD500 User Manual
- 88 -
Function Code Parameter Name Setting Range Default Property
F3-14 Digital setting of voltage
IRU9)VHSDUDWLRQ
0 V to rated motor voltage 0 V
ƿ
F3-15 9ROWDJHULVHWLPHRI9)VHSDUDWLRQ 0.0s to 1000.0s 0.0s
ƿ
F3-16 Voltage decline time
RI9)VHSDUDWLRQ
0.0s to 1000.0s 0.0s
ƿ
F3-17 Stop mode selection
IRU9)VHSDUDWLRQ
0: Frequency and voltage declining
to 0 independently
1: Frequency declining after voltage declines to 0
0
ƿ
F3-18 Overcurrent stall prevention level 50% to 200% 150%
ƾ
) Overcurrent stall
prevention selection
0, 1 1
ƾ
F3-20 Overcurrent stall prevention gain 0 to 100 20
ƿ
F3-21 Speed multiplying overcurrent
stall prevention level
compensation factor
50% to 200% 50%
ƾ
F3-22 Overvoltage stall prevention level 650 to 800 V 760 V
ƾ
F3-23 Overvoltage stall
prevention selection
0, 1 1
ƾ
F3-24 Overvoltage stall prevention
frequency gain
0 to 100 30
ƿ
F3-25 Overvoltage stall
prevention voltage gain
0 to 100 30
ƿ
F3-26 Overvoltage stall prevention
max. frequency limit
0 to 50 Hz 5 Hz
ƾ
Group F4: Input Terminals
F4-00 DI1 function selection WR 1
ƾ
F4-01 DI2 function selection WR 4
ƾ
F4-02 DI3 function selection WR
ƾ
F4-03 DI4 function selection WR 12
ƾ
F4-04 DI5 function selection WR 13
ƾ
F4-05 DI6 function selection WR 0
ƾ
F4-06 DI7 function selection WR 0
ƾ
F4-07 DI8 function selection WR 0
ƾ
F4-08 ',IXQFWLRQVHOHFWLRQ WR 0
ƾ
) DI10 function selection WR 0
ƾ
F4-10 ',ÀOWHUWLPH 0.000s to 1.000s 0.010s
ƿ
F4-11 Terminal command mode 0 to 3 0
ƾ
F4-12 7HUPLQDO83'2:1UDWH WR+]V +]V
ƿ
F4-13 AI1 curve min. input 0.00 V to F4-15 0.00 V
ƿ
F4-14 Corresponding percentage
of AI1 curve min. input
-100.00% to 100.0% 0.0%
ƿ
F4-15 AI1 curve max. input F4-13 to 10.00 V 10.00 V
ƿ
F4-16 Corresponding percentage
of AI1 curve max. input
-100.00% to 100.0% 100.0%
ƿ
F4-17 $,ÀOWHUWLPH 0.00s to 10.00s 0.10s
ƿ
F4-18 AI2 curve min. input 0.00 V to F4-20 0.00 V
ƿ
) Corresponding percentage
of AI2 curve min. input
-100.00% to 100.0% 0.0%
ƿ
F4-20 AI2 curve max. input F4-18 to 10.00 V 10.00 V
ƿ
F4-21 Corresponding percentage
of AI2 curve max. input
-100.00% to 100.0% 100.0%
ƿ
F4-22 $,ÀOWHUWLPH 0.00s to 10.00s 0.10s
ƿ
efesotomasyon.com

Table of Contents