MD500 User Manual 6. Parameter Table
Function Code Parameter Name Setting Range Default Property
Group F8: Auxiliary Functions
F8-00 Jog running frequency reference 0.00 Hz to maximum frequency 2.00 Hz
ƿ
F8-01 Jog acceleration time 0.0s to 6500.0s 20.0s
ƿ
F8-02 Jog deceleration time 0.0s to 6500.0s 20.0s
ƿ
F8-03 Acceleration time 2 0.0s to 6500.0s Model
dependent
ƿ
F8-04 Deceleration time 2 0.0s to 6500.0s Model
dependent
ƿ
F8-05 Acceleration time 3 0.0s to 6500.0s Model
dependent
ƿ
F8-06 Deceleration time 3 0.0s to 6500.0s Model
dependent
ƿ
F8-07 Acceleration time 4 0.0s to 6500.0s 0.0s
ƿ
F8-08 Deceleration time 4 0.0s to 6500.0s 0.0s
ƿ
) )UHTXHQF\MXPS 0.00 Hz to max. frequency 0.00 Hz
ƿ
F8-10 )UHTXHQF\MXPS 0.00 Hz to max. frequency 0.00 Hz
ƿ
F8-11 )UHTXHQF\MXPSEDQG 0.00 Hz to max. frequency 0.00 Hz
ƿ
F8-12 )RUZDUG5HYHUVHURWDWLRQ
dead-zone time
0.0s to 3000.0s 0.0s
ƿ
F8-13 Reverse RUN selection 0, 1 0
ƿ
F8-14 Running mode when
frequency reference lower
than frequency lower limit
0 to 2 0
ƿ
F8-15 Droop rate 0.00% to 100.00% 0.00%
ƿ
F8-16 Accumulative power-
on time threshold
0 to 65000 h 0 h
ƿ
F8-17 Accumulative running
time threshold
0 to 65000 h 0 h
ƿ
F8-18 Startup protection selection 0, 1 0
ƿ
) Frequency detection level 1 0.00 Hz to max. frequency 50.00 Hz
ƿ
F8-20 Frequency detection
level 1 hysteresis
0.0% to 100.0% 5.0%
ƿ
F8-21 Detection width of
frequency reference
0.00 to 100% 0.0%
ƿ
F8-22 6HOHFWLRQRIIUHTXHQF\MXPS
GXULQJDFFHOHUDWLRQGHFHOHUDWLRQ
0, 1 0
ƿ
F8-25 Frequency point of switchover
of accel time 1 and accel time 2
0.00 Hz to max. frequency 0.00 Hz
ƿ
F8-26 Frequency point for switchover
of decel time 1 and decel time 2
0.00 Hz to max. frequency 0.00 Hz
ƿ
F8-27 6HOHFWLRQRIWHUPLQDOMRJSUHIHUUHG 0, 1 0
ƿ
F8-28 Frequency detection level 2 0.00 Hz to max. frequency 50.00 Hz
ƿ
) Frequency detection
level 2 hysteresis
0.0% to 100.0% 5.0%
ƿ
F8-30 Detection of frequency 1 0.00 Hz to max. frequency 50.00 Hz
ƿ
F8-31 Detection width of frequency 1 0.0% to 100.0% (max. frequency) 0.0%
ƿ
F8-32 Detection of frequency 2 0.00 Hz to max. frequency 50.00 Hz
ƿ
F8-33 Detection width of frequency 2 0.0% to 100.0% (max. frequency) 0.0%
ƿ
F8-34 Zero current detection level 0.0% to 300.0% (rated motor current) 5.0%
ƿ
F8-35 Zero current detection delay 0.01s to 600.00s 0.10s
ƿ
F8-36 Output overcurrent threshold 0.0% (no detection)
0.1% to 300.0% (rated motor current)
200.0%
ƿ
efesotomasyon.com