EtherCAT Communication
94
Table 5–6 Parameters of drive unit
Para.
No.
Name
Value Range Setpoint Description
F0‑02
Command source
selection
0: Operating panel of
the power supply
unit/LCD operating
panel/Software tool
1: Terminal
2: Communication
2
For the drive unit, set
this parameter to 2.
F0‑03
Main frequency
source X selection
0: Digital setting
(preset frequency
(F0‑08) that can be
changed by pressing
UP/DOWN; non‑
retentive at power
failure)
1: Digital setting
(preset frequency
(F0‑08) that can be
changed by pressing
UP/DOWN; retentive
at power failure)
2: AI1
3: AI2
4: AI3
5: Reserved
6: Multi‑reference
7: Simple PLC
8: PID
9: Communication
10: Reserved
9
For the drive unit, set
this parameter to 9.