- 79 -
4 Operation Panel
4
Function
Code
Name Unit Meaning Display Examples
H0B-41
Input terminal
state upon
displayed fault
-
It indicates the high/low level state
of the 24 DI terminals when the
fault displayed in H0B-34 occurs.
The viewing method is the same
as that of H0B-03.
When there is no fault, H0B-41
displays that all DI terminals are
low, and the corresponding decimal
value is "0."
For example, the value of
H0B-41=0x431 read by the
commissioningsoftwareis:
The corresponding binary value is
"00000000 00000100 00110001."
Thekeypaddisplayisasfollows:
DI9
DI12
DI11
DI14
DI13DI15
DI10DI16
DI1
DI4
DI3
DI6
DI5DI7
DI2DI8
DI17
DI20
DI19
DI22
DI21DI23
DI18DI24
H0B-43
Output terminal
state upon
displayed fault
-
It indicates the high/low level state
of the 6 DO terminals when the
fault displayed in H0B-34 occurs.
The viewing method is the same
as that of H0B-05.
When there is no fault, H0B-42
displays that all DO terminals are
low, and the corresponding decimal
value is "0."
H0B-43=3isdisplayedasfollows:
DO3 DO1
DO2
High
1
High
1
Low
0
Low
0
Low
0
Low
0
DO5
DO4DO6
H0B-53
Position
deviation
counter
(32-bit decimal
display)
Reference
unit
Position deviation = Total input
position references
(reference unit) -
Totalencoderfeedbackpulses
(reference unit)
10,000 reference units is displayed
asfollows: