Intel® Server Board S1200BT TPS Appendix B: Integrated BMC Sensor Tables
Revision 1.0
Intel order number G13326-003
125
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading Type
Event Offset Triggers
Contrib. To System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-by
Power Supply 2
+12V % of Maximum
Current Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Processor Status
(P1 Status)
70h
All
Processor
07h
Sensor Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor Thermal
Margin
(P1 Therm Margin)
74h
All
Temperature
01h
Threshold
01h
__
__
-
Analog
R, T
A
Processor Thermal
Control %
(P1 Therm Ctrl %)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog
Trig
Offset
A
Catastrophic Error
(CATERR)
80h
All
Processor
07h
Digital Discrete
03h
01 State Asserted
Non-fatal
As and
De
Trig
Offset
M
MSID Mismatch
(MSID Mismatch)
81h
All
Processor
07h
Digital Discrete
03h
01 State Asserted
Non-fatal
As and
De
Trig
Offset
M
Processor
Population Fault
(CPU Missing)
82h
All
Processor
07h
Digital Discrete
03h
01 State Asserted
Fatal
As and
De
Trig
Offset
M
Processor VRD
Temperature
(P1 VRD Hot)
90h
All
Temperature
01h
Digital Discrete
05h
01 - Limit exceeded
Fatal
As and
De
Trig
Offset
M
Power Supply 1 Fan
Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Threshold
01h
Analog
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Threshold
01h
Analog

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200BTS and is the answer not in the manual?

Intel S1200BTS Specifications

General IconGeneral
ChipsetIntel C204 Chipset
Form FactorMicroATX
Processor SocketLGA 1155
Number of Processors Supported1
Number of Memory Slots4
Processor SupportIntel Xeon E3-1200 series
Memory SupportDDR3 ECC UDIMM
Expansion Slots1 PCI-E x16 Gen3, 1 PCI-E x4 Gen2, 1 PCI-E x1 Gen2, 1 PCI 32bit/33MHz
Storage4 x SATA 3Gb/s, 2 x SATA 6Gb/s
Network InterfaceDual Gigabit Ethernet ports
Memory Speed1333 MHz
RAID SupportedRAID 0, 1, 5, 10
USB Ports4 rear

Related product manuals