SE7500CW2 Connectors and Jumper BlocksSE7500CW2 Server Board Technical Product Specification
90
Revision 1.40
Table 51. VGA Connector Pin-out (J42)
Pin Signal Name
1 Red (analog color signal R)
2 Green (analog color signal G)
3 Blue (analog color signal B)
4 No connection
5 GND
6 GND
7 GND
8 GND
9 Fused VCC(+5V)
10 GND
11 No connection
12 DDCDAT
13 HSYNC (horizontal sync)
14 VSYNC (vertical sync)
15 DDCCLK
8.9 NIC Connectors
The SE7500CW2 server board supports two NIC RJ45 connectors. The following table details
the pin-out of the connector.
Table 52. RJ-45 Connector Pin-outs (J47)
Signal Name Pin Pin Signal Name
TXP (Primary) 1 9 PRI_SPEEDLED
TXM (Primary) 2 10 SB3V
RXP (Primary) 3 11 PRI_LILED
Connected to Pin 5 4 12 PRI_ACTLED_FB
Connected to Pin 4 5 13 TXP (Secondary)
RXM (Primary) 6 14 TXM (Secondary)
GND 7 15 RXP (Secondary)
GND 8 16 Connected to Pin 17
8.10 ATA Connectors
Intel Server Board SE7500CW2 provides two 40-pin ATA-100 connectors and two 40-pin ATA-
100 RAID connectors . The pin-out for all four connectors is identical and is listed in the following
table.