EasyManua.ls Logo

Intel SE7500CW2 - Table 25: Console Redirection Submenu

Intel SE7500CW2
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SE7500CW2 Server Board Technical Product Specification System BIOS
61
Revision 1.40
(default)
6.5.6.5 Console Redirection Submenu
To access this submenu, select Advanced on the menu bar at the top of the screen and then
Console Redirection.
Main Advanced Security Power Boot System Exit
I/O Device Configuration
On Board Device
PCI Configuration
Server Menu
Console Redirection
Event Logging
Hardware Monitor
Table 26 lists the options available through the Console Redirection submenu. This submenu
provides additional options to configure the console.
Table 26: Console Redirection Submenu
Feature Choices Description
COM Port Address Disabled
(default)
On-board
COM A
On-board
COM B
When enabled, console redirection uses the I/O port
specified. All keyboard/mouse and video will be directed to
this port. This setting is designed to be used only under
DOS in text mode.
Baud Rate 300
1200
2400
9600
19.2k
(default)
38.4k
57.6K
115.2k
When console redirection is enabled, specifies the baud
rate to be used.
Console Type PC ANSI
(default)
VT100
Enables the specified console type.
Flow Control None
XON/XOFF
CTS/RTS
(default)
None disallows flow control.
XON/XOFF is software-based asynchronous flow control.
CTS/RTS is hardware-based flow control.
When EMP is sharing the COM port as console redirection,
the flow control must be set to CTS/RTS.