1 Low Pressure Filter
2 Fluid Level
3 Drain Plug
4 Reservoir
5 Hour Meter
6 High Pressure Filter
7 Hydraulic Pressure Gage
8 Accumulator
9 Heat Exchanger
10 Motor
11 Temperature Gage
12 Oil Fill

The hydraulic power unit has three methods of protecon. The thermal overload relay on the motor
starter protects the motor from damage due to overheang or overcurrent. To reset this error push the
blue reset buon. The tank level indicator has a switch that will shut o the unit if the oil level gets too
low. The level must be restored before the unit will start again. At the boom of the tank level indicator
is a thermometer with a switch that will shut o the unit if the oil temperature gets too high. The
temperature must drop down to normal before the unit will start again.