User manual of EC160 elevator intelligent integrated machine Function parameters
127
Function
code
Instruction Setting rangedefault value Remarks
F0_05
Floor opening mode of parallel
outside calling
0~20
Not modify
in running
0: main and sub elevator opening at the same time
1: main elevator opening
2: sub elevator opening
Function
code
Instruction Setting rangedefault value Remarks
F0_06
Reset mode of running fault
overtime
0~10
Not modify
in running
0: manual reset
1: returning to leveling automatically
Function
code
Instruction Setting rangedefault value Remarks
F0_07 MF definition of IND 0~31
Not modify
in running
0: original definition
1: keep opening delay
2: select front/rear door
3: fire fighter input
Function
code
Instruction Setting rangedefault value Remarks
F0_08 Internal command limit times 0~50
Not modify
in running
0: without LL function
1-5: record signal times limit when LL