User manual of EC160 elevator intelligent integrated machine Function parameters
128
Function
code
Instruction Setting range【default value】 Remarks
F0_09 Dual door control mode 0~1【1】
Not modify
in running
0: dual control box mode
1: single control box mode
Set car logic to 3 when selecting dual control box mode. (Refer to the
set value of car logic1.)
Function
code
Instruction Setting range【default value】 Remarks
F0_10
Output landing of fire forced
landing
0~1【0】
Not modify
in running
0: output after forced landing
1: output only in the home floor after forced landing
Function
code
Instruction Setting range【default value】 Remarks
F0_11
Floor internal command
opening enabling
0~1【0】
Not modify
in running
0: disabled
1: enabled (applicable to IC card or no open button)
Function
code
Instruction Setting range【default value】 Remarks
F0_12 LINE1 multi-function definition 0~40【24】
Not modify
in running
F0_13 LINE2 multi-function definition 0~40【25】
F0_14 LINE3 multi-function definition 0~40【30】
Definition of F0_12~F0_14:
1 no definition 21 motor thermal protection
2 no definition
22 fire action input
3 medium speed down forced speed-changing
switch
23 no definition