User manual of EC160 elevator intelligent integrated machine EC160 configuration
7
No. Type Function name Function instruction Remarks
operation all calling records and run to the home floor
at the fastest speed. After that, output fire
signal to keep the door open. If the elevator
is running reversely, stop at the nearest
leveling position and drive to the home floor
and keep the door open.
49 Fire service
2 modes of fire service after the elevator
returns to the home floor: a. fire fighter
action by switching the switch in the control
box; b. fire fighter action after the waiting
delay time. Various modes can be selected
by F0_03 and the door will be closed by the
close button for fire (car top instruction
board FRCL).
Function
selection
50 Seismic operation
When the input signal acts, the elevator will
stop and open at the nearest leveling
position.
Function
selection
51 Test running
The function is used in debugging or a
fatigue test of a new elevator. Operate the
elevator in close mode by F0_16 and shield
outside calling.
Function
selection
52 Arrival gong
Ring when the elevator arrives at the door
area.
Function
53
Light and fan off
when stand-by
The light and fan will be off during free
energy-saving delay T0_03 when the door
is closed and no internal command and
outside calling signal. The light and fan will
be on automatically in command response.
Function
selection
54
Door
operator
Inspection
open/close door
If the door lock circuit is off, press up/down
button to get the closing command. When
the circuit is on, the elevator will run
up/down.
If the elevator stops at the door area, press
the up/down button at the same time to get
Standard