User manual of EC160 elevator intelligent integrated machine Function parameters
133
Function
code
Instruction Setting rangedefault value Remarks
F0_23 MF definition of DS 0~655350
Not modify
in running
0: original definition
1: opening keeping delay button
2: front/rear door selection
3: car firefighter input
Function
code
Instruction Setting rangedefault value Remarks
F0_24 Dual door area selection 0~655350
Not modify
in running
1: Enable dual door area
2: Dual door area replaces slow limit switch
4: Return to leveling and correct pulses in the state of dual door area
Function
code
Instruction Setting rangedefault value Remarks
F0_26
Start time 1 of time sharing
service
0~23590
Not modify
in running
F0_27
Stop time 1 of time sharing
service
0~23590
F0_28
Time 1 of time sharing service
Stop at 1~16 floors
0~655350
F0_29
Time 1 of time sharing service
Stop at 17~32 floors
0~655350
F0_30
Time 1 of time sharing service
Stop at 33~48 floors
0~655350
F0_31
Time 1 of time sharing service
Stop at 49~64 floors
0~655350
F0_32
Start time 2 of time sharing
service
0~23590
Not modify
in running