User manual of EC160 elevator intelligent integrated machine Complete product description
187
G data management
H system information
setting 04 T4
05 T5
Function
code
Description
Setting range【default
value】
Remarks
P2_00 Idle time threshold 000.0~600.0【20】s
Note: when the elevator cannot run and timeout, exit group control time.
P2_01
Time threshold of
external selection
00.0~10.0【2】s
Note: time threshold for responding to external selection
P2_02
Time threshold of
internal selection
00.0~10.0【2】s
Note: time threshold for responding to internal selection
P2_03
Time threshold of
separate standby
00000~60000【0】s
Note: separate standby is valid at non-zero-when separate standby time is up without running
direction, return to the set standby floor.
P2_04 Customized 0000.0~6553.5【45】s
Note: error duration that the elevator did not run with direction and timeout
P2_05 Customized 0000.0~6553.5【45】s
Note: error duration that the elevator had dispatch command without direction (2s)
9.4.9.8 Parameters setting inquiry---running mode setting
【main menu】
A system control
B fault record
C language selection
D parameters setting
inquiry
E password setting
F system autotuning
G data management
H system information
【parameters setting
inquiry】
P0 system clock
setting
P1 floor of home
landing
P2 time setting
P3 running mode
setting
【P3 running mode
setting】
00 timing rush hour mode
enabling
01 start time of up rush
hour
02 end time of up rush hour
03 start time of down rush
hour
04 end time of down rush
hour