User manual of EC160 elevator intelligent integrated machine Complete product description
186
Standby floor in rush hour up; separate standby-elevator A returns to standby floor (P2_03=0, the
function is invalid)
P1_01 Home landing in middle 00~64【00】
Default floor is in the
middle
Separate standby-elevator B returns to standby floor (P2_03=0, the function is invalid)
P1_02 Home landing at top 00~64【64】 Default floor is at the top
Standby floor in rush hour down; separate standby-elevator C returns to standby floor (P2_03=0,
the function is invalid)
P1_03
Group control home
landing 4
00~64【00】
Separate standby-elevator D returns to standby floor (P2_03=0, the function is invalid)
P1_04
Group control home
landing 5
00~64【00】
Separate standby-elevator E returns to standby floor (P2_03=0, the function is invalid)
P1_05
Group control home
landing 6
00~64【00】
Separate standby-elevator F returns to standby floor (P2_03=0, the function is invalid)
P1_06
Group control home
landing 7
00~64【00】
Separate standby-elevator G returns to standby floor (P2_03=0, the function is invalid)
P1_07
Group control home
landing 8
00~64【00】
Separate standby-elevator H returns to standby floor (P2_03=0, the function is invalid)
P1_08 VIP floor 00~64【00】
9.4.9.7 Parameters setting inquiry---time setting
【main menu】
A system control
B fault record
C language selection
D parameters setting
inquiry
E password setting
F system autotuning
【parameters setting
inquiry】
P0 system clock
setting
P1 floor of home
landing
P2 time setting
P3 running mode
【P2 time setting】
00 idle time threshold
01 time threshold of
external selection
02 time threshold of
internal selection
03 time threshold of
separate standby