User manual of EC160 elevator intelligent integrated machine Fault code
204
2.After the
opening signal
output for 5s, the
lock still does not
disconnect
misaction of the
switch
3.Check the door
operator
11 33
Do not stop
at the door
area
Elevator
protection
caused by other
faults
Analyze with other
faults
Fault tips
12 34
DEC
overtime
The deceleration
time exceeds the
time calculated
in the parameter
1.Sliding of the
elevator rope
2.Wrong
parameters setting
Stop
immediately;
reset
automatically
13 35
Single floor
running
overtime
fault
1.Signal loss in
the door area
2.Motor stall or
car blocked
3.Too high floor
1.Check the signal
in door area
2.Check the
tractor
3. Wrong
parameters setting
Stop
immediately;
fault reset
manually
14 37
Whole
running
overtime
fault
1.Signal loss in
the door area
2.Motor stall or
car blocked
3.For
deceleration
1.Check the signal
in door area
2.Check the
tractor
3. Wrong
parameters setting
Stop
immediately;
fault reset
manually
15 40
Abnormal
signal in
door area
Keep in the door
area after start
quickly for 5s
1.Check the
braking device is
open
2.Check the
switch in door area
Stop
immediately;
fault reset
manually
16 42
Forced DEC
switch of the
bottom and
top floor act
at the same
Forced
deceleration
switch of the
bottom and top
floor act at the
1.Check the
forced switch is
damaged or offline
2.Check the
corresponding
Stop
immediately;
fault reset
automatically

Table of Contents