User manual of EC160 elevator intelligent integrated machine Fault code
205
time same time logic setting
17 43
Earthquake
action
The main board
detects the
earthquake
1.Check the
corresponding
logic setting
2.Corresponding
detection point
damage
Function tips
18 46
Abnormal
elevator
speed
The running
speed of the
elevator exceeds
115% of the
rated speed
1.Check the speed
feedback of the
encoder
2.Check the
parameters setting
Stop
immediately;
fault reset
automatically
19 47
Lower limit
switch action
Lower limit
switch action
1.Check the
installation
position of the
lower limit switch
2.Check the
corresponding
logic setting
3.Check the
switch wiring
Stop
immediately;
fault reset
automatically
20 48
Upper limit
switch action
Upper limit
switch action
1.Check the
installation
position of the
upper limit switch
and connection
2.Check the
corresponding
logic setting
Stop
immediately;
fault reset
automatically
21 50
Overtime of
the running
contactor
closing
No feedback
after the running
contactor closing
1.Replace the
contactor
2.Check the
external wiring
3.Check the
corresponding
Stop
immediately;
fault reset
automatically