User manual of EC160 elevator intelligent integrated machine Fault code
208
29 58
Hardware
enabling
adhesion
No detection of
the signal after
the elevator
starts
1.Check the
connection cables
of the IO board
2.Check the
contactor and
connection
Stop
immediately;
fault reset
automatically
30 59
Star-delta
contactor
opening
overtime
1.Detection of
the signal after
the elevator
stops
2.Set MF input to
star-delta
independent
output by
accident
1.Check
peripheral wiring
2.Check the
corresponding
logic setting
3.Check the
definition of MF
input
Prohibit the
elevator
starting; fault
reset
automatically
31 60
Opening
fault
No detection of
the signal after
opening for 20s
1.Clean the sill of
the door operator
2.Enlarge the low
speed torque of
the door operator
3.Check the
corresponding
logic setting
Fault tips
32 61
Closing fault
No detection of
the signal after
closing for 10s
1.Clean the sill of
the door operator
2.Enlarge the low
speed torque of
the door operator
3.Check the
corresponding
logic setting
Fault tips
33 62
Door
closed/door
open act at
the same
Limit switch of
door closed/open
act at the same
time
1.Limit switch
damage
2.Check the
corresponding
Stop
immediately;
fault reset
automatically

Table of Contents