User manual of EC160 elevator intelligent integrated machine Fault code
209
time logic setting
34 64
Safety touch
pad/beam
action
overtime
Safety touch
pad/continuous
action of beam
overtime
1.Human
obstruction
2.Detection point
damage,
disconnection or
short circuit
3.Check the
corresponding
logic setting
Fault tips
35 65 Auto aid
The detection of
auto aid signal
by the main
board
1.Check the
corresponding
logic setting
2.Corresponding
detection point
damage
Function tips
36 66
Door lock
block when
door closed
Door lock block
when door
closed
1.Adjust the digital
position of the
door operator
2.Exchange lock
device
3.Check the
corresponding
logic setting
Stop
immediately;
fault reset
automatically
37 70
UP/DOWN
slow limit
switch act at
the same
time
UP/DOWN slow
limit switch act at
the same time
1.Switch damage
or disconnection
2.Check the
corresponding
logic setting
Stop
immediately;
fault reset
automatically
38 71
UP/DOWN
speed forced
DEC
switches act
at the same
time
The forced
deceleration
switches act at
the same time
1.Switch damage
or disconnection
2.Check the
corresponding
logic setting
Emergency
deceleration to
stop; fault reset
automatically